Dear Peter,
The compressor controller outputs are ECL. So you do not need to buy an
other SIS3600 unit.
I only have 2 spare Trigger units in Louvain and they are as the former
one, without flash memory. Noting is presently programmed to build new
ones with non volatile memory. We will think on that when some free
time occurs for our technicians. Indeed a new layout must be draw for
such an option.
René
Le 17-mai-05, à 22:15, Peter Kammel a écrit :
> Dear Rene,
>
> We are just buying a SIS3600 for MuLan to process the outputs
> of your LLN trigger unit. Does your trigger unit output
> ECL or LVDS ? If it is LVDS, we would need to buy an
> LVDS SIS3600, which would be different from the ECL ones
> you are using.
>
> Please advice.
>
> Related to that. Are you considering building more of the trigger
> units (potentially with non volatile program memory). We would
> be interested of purchasing 1 or 2 from you, if we can afford
> that :)
>
> Thanks and best regards
>
> Peter
>
>
> ----------------------------
> Dear Peter,
> thanks a lot for your inquiry.
> Lead time would be in the order of 2 weeks.
> 2 x SIS3600 ECL USD 1780,-/unit
> 2 x SIS3600 LVDS USD 1980,-/unit
> I'm sorry, but we do not have an educational price scheme.
> A formal quote can be send by our US rep Drivesoft
> (I'm cc'ing Michael Doebelin on this email message).
> Best regards
> Matthias
>
> ----- Original Message -----
> From: "Peter Kammel" <kammel@npl.uiuc.edu>
> To: "Dr. Matthias Kirsch" <matthias.kirsch@struck.de>
>
>
>
> ---------- Forwarded message ----------
> Date: Wed, 09 Feb 2005 15:05:45 +0100
> From: "[ISO-8859-1] René Prieels" <R.Prieels@fynu.ucl.ac.be>
> To: Peter Kammel <kammel@npl.uiuc.edu>
> Subject: Re: questions
>
> Dear Peter,
>
> 1) The LLN trigger unit is able to receive LVDS or ECL signals.
>
>
>
---------------------------------------------------------------------
René PRIEELS Universite Catholique
de Louvain
email: R.Prieels@fynu.ucl.ac.be Departement de Physique / FYNU
Tel : ++ 32 (0)10 / 47 32 09 Chemin du cyclotron, 2
Fax : ++ 32 (0)10 / 45 21 83 B-1348 Louvain-la-Neuve -
BELGIUM
---------------------------------------------------------------------