[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

my note on your result



Dear Brendan,

I think I have screwed up yesterdays calculation.

Rethinking it today, I believe you have solved the oxygen puzzle
with your present analysis,

So given your numbers

            Yield EVH ppm    humidity (in atomic ppb)
low flux    450              1140

high flux   120              360

please confirm that these numbers now are correct

taking  delta_Y / delta_humidity = 330 / 0.780 = 423

comparing that to the common 397 in all our tables

this clearly indicates that everything is
consistent with literature, MuCAP does not have a problem
and we have been puzzled for the last 10 monthes
because Claude went too early skiing.

  good night, see you all soon

       Bernhard








> I used a common scale factor to multiply the humidity sensor (250)
> For the water low
>       HS = 180
> For the water high
>       HS = 570
> -Brendan
>
> Bernhard LAUSS wrote:
>> Great,
>>
>> can you also tell me the humidity sensor values for
>> the water low and high flux measurements
>>
>> thanks
>> Bernhard
>>
>>
>>     _/   _/         _/                 Dr. Bernhard Lauss
>>    _/   _/         _/                  Institut Laue-Langevin
>>   _/   _/         _/                   B.P.156 - 6 rue Jules Horowitz
>>  _/   _/         _/                    38042 Grenoble - Cedex 9
>> _/   _/_/_/_/   _/_/_/_/               France
>>
>>                     Tel:+33-(0)4-7620 7134
>> Fax:+33-(0)4-7620 7777
>>
>>                     Email: lauss@ill.fr
>>
>>
>>
>> Brendan Kiburg wrote:
>>> Dear Bernhard,
>>>  Here are some of the values that I have fit so far, relative to a
>>> fit for the main data:
>>>
>>> Nitrogen :   dLambda = +2008 +/- 47
>>>                   Yield EH  ~ 1750 / ppm
>>>                   Yield EVH ~ 1400 / ppm
>>>
>>>                   dL/Y ~ 1.15+/- 0.03 Hz/ppm Y  (EH)
>>>                                1.48+/- 0.04 Hz/ppm Y (EVH)
>>>
>>> Water, low flux:
>>>                 dLambda = +110 +/- 95
>>>                  Yield EH  ~  150 / ppm
>>>                  Yield EVH ~ 120 / ppm
>>>
>>>                  dL/Y ~ 0.786 +/- 0.633 (EH)
>>>                  dL/Y ~ 0.92 +/- 0.79 (EVH)
>>>
>>> Water, high flux
>>>                 dLambda = 657+/- 61 Hz
>>>                 Yield EH = 550 / ppm
>>>                 Yield EVH = 450 / ppm
>>>                 dL /Y ~ 1.19 +/- 0.11  (EH)
>>>                 dL/Y  ~  1.46 +/- 0.14 (EVH)
>>>
>>> So, I still have some kinks to work out and I would like to improve
>>> the precision on the Yield numbers also . Most of the fits are
>>> reasonable for the lifetime and I am using 120 ppm impact parameter
>>> cuts.
>>>
>>> I will try to improve the precision on the reference lifetime to
>>> reduce the errors as well, but this should be a general starting
>>> point.  Most numbers are higher than Tom's quoted 0.8 dL/Y for Run 8
>>> ....not sure what to make of it yet.
>>>
>>> It looks like the change in lifetime will roughly scale with the
>>> humidity sensor tho.
>>>
>>> Have a good trip,
>>> Brendan
>
>


-- 
Bernhard Lauss
Institut Laue-Langevin
6, Rue Jules Horowitz, BP 156
38042 Grenoble
France
Tel: +33 (0)4 76 20 71 34
Fax: +33 (0)4 76 20 77 77
email: lauss@ill.fr

-- 
Bernhard Lauss
Institut Laue-Langevin
6, Rue Jules Horowitz, BP 156
38042 Grenoble
France
Tel: +33 (0)4 76 20 71 34
Fax: +33 (0)4 76 20 77 77
email: lauss@ill.fr